Kingwell News
Product Detail

RTTS_packer

Product Details


The RTTS packer

rtts packer testing.jpg

Topic RTTS Packer.pdf


is a fullopening, hookwall packer used for testing, treating, and squeeze cementing operations. Generally, it is necessary to run the RTTS Packer with an RTTS Circulating Valve assembly, or Model 2 RTTS Circulating Valve assembly for casing sizes 8 5/8 in. and larger. It is also recommended, but optional, to include a safety joint in the string.

The packer body includes a J-slot mechanism, mechanical slips, packer elements, and hydraulic slips. Large, heavy-duty slips in the hydraulic hold down mechanism help prevent the tool from being pumped up the hole. Drag springs operate the J-slot mechanism on ≤ 3 1/2-in. (88.9-mm) packer bodies, while larger packer sizes≥ 4-in. (101.6 mm) use drag blocks. Automatic J-slot sleeves are standard equipment on all packer bodies.
1.The full-opening design of the packer mandrel bore allows large volumes of fluid to pump through the tool. Tubing-type guns and other wire line tools can be run through the packer
2.The packer can be set and relocated as many times as necessary with simple tubing manipulation.
3.Tungsten carbide slips provide greater holding ability and improved wear resistance in high-strength casing. Pressure through the tubing activates the slips in the hydraulic hold-down mechanism.






Setting the RTTS Packer


To set the packers, follow these steps:


1.Run the tool slightly below the setting position.


2.Lift to the setting position.

3.Rotate the pipe to the right several turns.


4.Maintaining right-hand torque in the pipe, slack off until the mechanical slips on the packer body begin to take weight.

5.Stop pipe movement and relieve torque by turning the pipe to the left. (Approximately onehalf


turn per 1,000 ft of pipe is usually sufficient; however, do not turn the pipe to the left any more than it was turned to the right in the setting process.)

6. As the left-hand torque is applied, move the tubing down until the required amount of weight is on the packer.



Drawing for RTTS Packer


Technical Parameters


Technical Parameters


Casing Size
(in.)
Casing Weight
Range lb/ft
Nominal Tool
OD in. (cm)
Minimum
ID in. (cm)
Top Thread
Connection
(female)
Lower Thread
Connection
(male)

9.53.79 (9.63)1.80 (4.57)3 3/32 in. 10 UNS2 3/8 in. 8 RD EUE
41/215.1-18.13.55(9.02)1.51 (3.84)2 11/16in. 10 UNS2 3/8 in. 8 RD EUE

11.6-13.53.75(9.53)1.80 (4.57)3 3/32 in. 10 UNS2 3/8 in. 8 RD EUE

233.75 (9.53)1.80 (4.57)3 3/32 in. 10 UNS2 3/8 in. 8 RD EUE
515-184.06 (10.31)1.80 (4.57)3 3/32 in. 10 UNS2 7/8 in. 8 RD EUE

11.5-134.25(10.79)1.80 (4.57)3 3/32 in. 10 UNS2 7/8 in. 8 RD EUE

23-264.25(10.79)1.90 (4.83)31/2 in. 8 UNS2 7/8in. 8 RD EUE
51/220-234.38(11.13)1.80 (4.57)3 3/32 in. 10 UNS2 7/8in. 8 RD EUE

13-204.55(11.56)1.80 (4.57)31/2 in. 8 UNS2 3/8 in. 8 RD EUE
615-235.06 (2.85)1.90 (4.83)31/2 in. 8 UNS2 7/8 in. 8 RD EUE
6 5/824-325.43(13.79)1.90 (4.83)31/2 in. 8 UNS2 7/8 in. 8 RD EUE
717-385.65 (14.35)2.40 (610)3 7/8 in. CAS
45/32 in. 8 UNS
2 7/8 in. IF
31/2 in. CAS
2 7/8 in. 8 RD EUE

49.55.25 (13.34)2.00 (5.08)3 1/2 in. 8 UNS2 7/8 in. 8 RD EUE
7 5/820-396.35 (16.13)2.40 (6.10)4 5/32 in. 8 UNS2 7/8 in. 8 RD EUE
31/2 in. IF
3 7/8 in. CAS
85/824-497.31 (18.57)3.00(7.62)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.
95/840-71.87.80 (19.81)3.00 (7.62)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.

29.343.58.15 (20.70)3.75 (9.53)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.
103/432.75-519.30 (23.62)3.75 (9.53)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.

55.5-818.85 (22.48)3.75(9.53)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.
113/438-5410.20 (25.91)3.75 (9.53)4 1/2 in. API IFT.J.4 1/2in. API IFT.J.

60-7110.10(25.65)3.75 (9.53)4 1/2in. API IFT.J.4 1/2in. API IFT.J.



Vulnerable Parts


We also always offer vulnerable parts of packer for our customers, such as packer rings inconel bolt, inconel drag-block, spring, o-ring, hydraulic slip, slip-retractor spring, mechanical slip, top shoe etc.



KINGWELL Circulating Valve


Introduction


The RTTS circulating valve is a locked-open/locked-closed valve that serves as both a circulating valve and a bypass. This valve was designed for use with the RTTS Packer. The RTTS circulating valve is automatically locked in the closed position when the packer is set. During testing and squeezing operations, the lock helps prevent the valve from being pumped open.



Operating Procedure


The RTTS Circulating Valve may be run directly above the packer body or farther up the workstring. The operating principle is based on lug movements in a J-slot. The lugs move with workstring manipulation. When the lug is in the upper position, the circulating valve is open; when the lug is in the lower position, the circulating valve is closed. The RTTS Circulating Valve is normally used in the following sequence:

1.Run in the hole.

2. Set the RTTS Packer.


3.Spot cement or acid, if necessary.


4.Performance test, treat, or squeeze job.


5.Pull out of the hole.


KINGWELL Safety Joint


Introduction


The RTTS Safety Joint is an optional tool that aids in removal of the workstring if the packer becomes stuck (cemented in, stuck in collapsed casing, etc.). To initiate the release of the safety joint, part a tension sleeve by pulling on the workstring with enough overpull to shear the tension sleeve.



Running the Safety Joint


1. The optional safety joint may be run above the circulating valve or between the circulating valve and the RTTS Packer body:

2. When the safety joint is run above the circulating valve, make it up directly into the top adapter of the valve.

3. When the safety joint is run between the circulating valve and the packer body, remove the adapter on the bottom of the safety joint and screw it into the top adapter of the safety joint. This procedure leaves a straight thread on the bottom of the joint, which can then be made up directly into the top of the packer body. The circulating valve can then be made up directly into the adapter on the top of the safety joint.


Kingwell Oilfield Machinery
Mr. Jerry Wang    CEO
Mobile / whatsApp: +86 18729329559
Email: kingwell@kingwelloilfield.com

Tel: 86+029-8860 1839
Fax: 86+029-8860 1839
Skype: xakingwell
Address: No.18 Fenghui South Road, Hi- tech Zone, Xi'an, China.
Ms.Yu
Int'l Sales Manager  PIC of Int'l Trade dept.
Cellphone/whatsApp: +86 13772083276
Email: Marketing@kingwelloilfield.com

Catherine Li
Marketing Manager
Cellphone/whatsApp: 0086 13379186892
Email: salesdst@kingwelloilfield.com
Linda
Business Development Manager
Mobile / whatsApp: +86 13379187081
Email: linda@kingwelloilfield.com

Grace  
in Charge of Perforating Material Dept.
Email: drilling@kingwelloilfield.com
Office Tel: 0086 88601839